Hello everyone! Today, I will introduce some precautions in the application of Roots vacuum pump Roots vacuum pump refers to a pair of sole-shaped rotor high-speed synchronous rotation of the mechanical vacuum pump. This kind of pump can't pump independently, its front stage needs to be equipped with oil seals and water rings, directly discharged into the atmosphere, its also widely used in industry, in order to improve the pump's limit vacuum, can be used in series Roots pump. Working principle and performance characteristics and Roots blower is basically the same, the main difference is that its rotor for the Roots type, Roots vacuum pump is mainly composed of two in the pump body reverse rotation of the rotor by a pair of synchronous gear drive. The rotors of Roots vacuum pump mesh in the pump body, but there is a gap. The size of the gap depends mainly on the viscosity of the liquid. It needs to be adjusted to exceed a certain viscosity range to increase the gap.
1, often check the oil level position. If it does not meet the requirements, it needs to be adjusted to meet the operating requirements of the Roots vacuum pump. The oil level standard shall prevail.
2, the oil change cycle of Roots vacuum pump is determined according to the actual use, which can meet the user's performance requirements and other considerations. Generally speaking, the new Roots pump should be pumped clean. It is recommended that the oil change about 100 hours, the oil can not be seen in the black metal powder, the period may be extended after the deadline.
3, often check the quality of oil, timely detection of oil deterioration, replacement of new oil, to ensure that the Roots vacuum pump works properly.
4、Generally, Roots vacuum pump should be inspected after 2000 hours of work to check the aging degree of rubber sealing, check whether the exhaust valve is cracked, and clean the dirt of the valve plate and exhaust valve seat in order to clean the whole Roots pump chamber parts, such as the rotor, rotor, spring and so on. Generally clean and dry with gasoline. Wipe the rubber with a dry cloth to dry it. When cleaning and assembling, put it gently with care and scrape it carefully.
5, Roots bearing to the bearing body lubricating oil, observe the oil level should be in the middle line of the oil, timely replacement or add lubricant.
6、Check whether the pipes and joints of Roots vacuum pump are loose, manually rotate Roots vacuum pump and observe whether it is flexible.
7、It should be reassembled after test run and the oil should be replaced twice after 2 hours. As a result of cleaning Roots vacuum pump will leave a certain amount of volatile content to operate normally, and then put into normal operation.
8、Start the motor. When the Roots vacuum pump is running normally, open the outlet pressure gauge and input Roots vacuum pump. If the corresponding pressure is displayed, gradually open the gate valve and check the motor load.
9, try to control the flow and head of Roots vacuum pump in the range shown on the label to ensure that the Roots vacuum pump is running to achieve a great energy-saving effect.